[SCHEDULER-1111]  "Open Before" time restricted to integral hours
Type Bug
Priority Medium
Severity Minor
Component Dispatch Scheduler Engine
Fixed In Version [3.6c3.6c
Versions Affected [3.63.6
Severity Closed
Resolution Complete
Reported By Bob Denny
Resources Bob Denny
Start Date 3/3/2014

Description
See this Comm Center post by Mark Williams. The test for open-before time contains an implicit integer conversion, resulting in the ability to open only 0, 1, 2, 3 etc. hours before sunset.

Comments
3/4/2014 11:38:36 AM   Bob Denny
SVN Comment
Author rbdenny
Repository svn+ssh://rbdenny@a2_svn_dc3/home/rbdenny/svn/astro/scheduler
SVN Revision 366
Affected files /trunk/Scheduler/AssemblyInfo.cs (Modified)
/trunk/Scheduler/Engine.cs (Modified)
Check-in comment OOps, this will be a 3.6c not 3.7, change versions. Engine 3.6.4 GEM:1111
3/3/2014 9:49:51 AM   Bob Denny
SVN Comment
Author rbdenny
Repository svn+ssh://rbdenny@a2_svn_dc3/home/rbdenny/svn/astro/scheduler
SVN Revision 364
Affected files /trunk/Help/RelNotes.htm (Modified)
/trunk/Scheduler/Engine.cs (Modified)
Check-in comment Fix open-before time GEM:1111