[SCHEDULER-1774]  SlewAltAz() - The telescope isn't connected!
Type Bug
Priority High
Severity Major
Component Dispatch Scheduler Engine
Fixed In Version [9.09.0
Versions Affected [8.38.3
Severity Closed
Resolution Complete
Reported By Bob Denny
Resources Bob Denny
Start Date 3/23/2021

Description
See this Comm Center thread by Stacey Mills. Yet another chicken and egg problem with close if idle and open in unsafe weather.

Comments
3/23/2021 2:14:18 PM   Bob Denny
SVN Comment
Author rbdenny
Repository svn+ssh://rbdenny@a2_svn_dc3/home/rbdenny/svn/astro/scheduler
SVN Revision 860
Affected files /trunk/Help/RelNotes.htm (Modified)
/trunk/Scheduler/ACPSequencer.cs (Modified)
/trunk/Scheduler/Engine.cs (Modified)
/trunk/Scheduler/ISequencer.cs (Modified)
/trunk/Scheduler/SimulatorSequencer.cs (Modified)
Check-in comment The combination of Startup in Unsafe Weather = False, Close if Idle with a specified scope idle position, and the observatory has never been cold started, and then the weather goes safe, it now knows not to try to move the scope to the idle position since the scope is not even powered up yet. Add ScopeConnected member to Sequencer interface. GEM:1774