[ACP-488]  Allow MaxIm's "Simple-AutoDark" for guiding?
Type Limitation
Priority Medium
Severity Minor
Component AcquireSupport library
Fixed In Version [
Versions Affected [5.1.115.1 Hot Fix 11
Severity Closed
Resolution Complete
Reported By Bob Denny
Resources Bob Denny
Start Date 1/1/0001

Description
It's possible that all I have to do to allow MaxIm's Simple Auto-Dark mode for guiding is to take one more full-frame image before starting the guider, after caculating the final exposure interval. It may be possible to skip this if Simple Auto-Dark is not selected in MaxIm, look at the scripting interface.

Comments
11/19/2010 8:59:29 AM   Bob Denny
SVN Comment
Author rbdenny
Repository svn+ssh://rbdenny@a2_svn_dc3/home/rbdenny/svn/astro/acp
SVN Revision 150
Affected files /trunk/ACP Help/autoguide.htm (Modified)
Check-in comment Doc update for ability to use MaxIm Simple Auto-Dark GEM:488
11/18/2010 10:29:44 PM   Bob Denny
Reopened for documentation update.
11/18/2010 8:21:46 AM   Bob Denny
This worked!. WIth that last full-frame guider image that was part of the ACP-490 Guider Image on Web Interface, it also allowed MaxIm to use Simple Auto-Dark for guiding. Closing.
11/17/2010 8:18:08 PM   Bob Denny
I added an additional guider exposure as part of the guider thumbnail issue ACP-490.
11/15/2010 5:22:39 PM   Bob Denny
See this Comm Center thread.