ACP-1919 - ACP Freezes if Weather Unsafe While Focusing
Estimated: 8 Hours 0 Minutes   Logged: 0 Hours 0 Minutes   Time Left: 8 Hours 0 Minutes
Print  |  Send  |  Refresh  |  Url
Type: Bug Bug
Priority: High High
Severity: Show Stopper Show Stopper
Status: Closed Closed
Resolution: Complete
Resources: Bob Denny
Reported By: Bob Denny
Component: Main Program
Fixed In Version: None
Versions Affected: 9.0
Start Date: 1/31/2024
Percent Complete:
Created:  2/1/2024 11:55:23 AM
Revised:
 6/12/2024 1:09:56 PM
Closed:  6/12/2024 1:09:40 PM
Resolved:  6/12/2024 1:09:49 PM

See this comm center thread by Alan Marsh. Steve Brady looked at this and discovered that I am not correctly waiting for FocusMax to run down. Add logic to wait properly for simple vs AcquireStar vs MultiStar modes, and wait for FMx to run down after Halt() right there within the script rundown logic.