ACP-1702 - Autoflat Fails for PlaneWave PWI2
Estimated: 2 Hours 0 Minutes   Logged: 1 Hours 0 Minutes   Time Left: 1 Hours 0 Minutes
Print  |  Send  |  Refresh  |  Url
Type: Bug Bug
Priority: High High
Severity: Major Major
Status: Closed Closed
Resolution: Complete
Resources: Bob Denny
Reported By: Bob Denny
Component: AcquireSupport library
Fixed In Version: 8.2.2
Versions Affected: 8.2.1
Start Date: 7/17/2019
Percent Complete:
Created:  7/17/2019 6:14:09 AM
Revised:
 12/6/2019 11:41:11 AM
Closed:  12/6/2019 11:40:26 AM
Resolved:  12/6/2019 11:40:26 AM

This issue dates back to November 2018, where ACP in the AcquireSupport.MoveFocuser() was hardcoded for PWI3. Since some customers have PWI2 and some will have PWI4, Kevin Ivarsen of PlaneWave supplied code in the FocusOffsets script to handle it. Somewhere I dropped the ball and didn't put that code into AcquireSupport. No documentation exists in the Comm Center as no ticket was filed for any of this. It reappeared at Don Elledge's as an Autoflat failure. The amazing thing is that this function is used during routine observing, yet it only appeared when running Autoflats.