ACP-1841 - Proper Synchronization Starting FocusMax
Estimated: 1 Hours 0 Minutes   Logged: 1 Hours 0 Minutes   Time Left: 0 Hours 0 Minutes
Print  |  Send  |  Refresh  |  Url
Type: Change Request Change Request
Priority: Low Low
Severity: Trivial Trivial
Status: Closed Closed
Resolution: Complete
Resources: Bob Denny
Reported By: Bob Denny
Component: AcquireSupport library
Fixed In Version: 9.0
Versions Affected: 8.3
Start Date: 6/25/2021
Percent Complete:
Created:  6/25/2021 12:01:56 PM
Revised:
 6/25/2021 2:13:56 PM
Closed:  6/25/2021 2:13:44 PM
Resolved:  6/25/2021 2:13:47 PM

Per Steve Brady, FocusMax has a property FocusControl.FocusMaxIsLoaded which can be used to synchronize startup of FocusMax as opposed to the 5 second wait. And by the way, the 5 seconds should be 15 seconds also. Use that property in AcquireSupport's Starting FocusMax logic, but fall back to the timer if that property is not supported by the version of FocusMax installed. He did not know when it was introduced.