Geminiclose
Gemini Password Reset

Please provide your username.

A password reset confirmation email will be sent to your email address.

Username
  • Projects

 
ACP-205 - Rotator controller disconnects when connected
Estimated: 1 Hours 0 Minutes   Logged: 1 Hours 0 Minutes   Time Left: 0 Hours 0 Minutes
Print  |  Send  |  Refresh  |  Url
Type: Bug Bug
Priority: High High
Severity: Show Stopper Show Stopper
Status: Closed Closed
Resolution: Complete
Resources: Bob Denny
Reported By: Bob Denny
Component: Rotator Control Applet
Fixed In Version: 5.1 HotFix 10
Versions Affected: 5.1 HotFix 9
Start Date: ?
Percent Complete:
Created:  10/9/2009 9:09:29 PM
Revised:
 10/9/2009 10:26:32 PM
Closed:  10/9/2009 10:26:32 PM
Resolved:  10/9/2009 10:21:09 PM

Bill Perkins - when AcqSupt calls SetupRotator(), it creates a RotControl then sets Connected to true. If RotControl is already running and connected, this causes RotControl to disconnect about a second thereafter! The logic in ACP.Rotator.Connected doesn't check to see (a) if it has already created a driver (e.g. RCOS), nor does it check if it is already connected.