Type:
|
Bug
|
|
Priority:
|
High
|
|
Severity:
|
Show Stopper
|
|
Status:
|
Closed
|
|
Resolution:
|
Complete
|
|
Resources:
|
Bob Denny
|
|
Reported By:
|
Bob Denny
|
|
Component:
|
Rotator Control Applet
|
|
Fixed In Version:
|
5.1 HotFix 10
|
|
Versions Affected:
|
5.1 HotFix 9
|
|
Start Date:
|
?
|
| Created: |
10/9/2009 9:09:29 PM |
| Revised: |
10/9/2009 10:26:32 PM
|
| Closed: |
10/9/2009 10:26:32 PM |
| Resolved: |
10/9/2009 10:21:09 PM |
|
Bill Perkins - when AcqSupt calls SetupRotator(), it creates a RotControl then sets Connected to true. If RotControl is already running and connected, this causes RotControl to disconnect about a second thereafter! The logic in ACP.Rotator.Connected doesn't check to see (a) if it has already created a driver (e.g. RCOS), nor does it check if it is already connected.
|
|
|
|
|
|
|
|
|
|
|
|
Are you sure that you want to reset the votes?