Geminiclose
Gemini Password Reset

Please provide your username.

A password reset confirmation email will be sent to your email address.

Username
  • Projects

 
ACP-740 - Checking CanSetPierSide Causes 2 Scope Drivers to Fail
Estimated: 1 Hours 0 Minutes   Logged: 1 Hours 30 Minutes   Excess Time: 0 Hours 30 Minutes
Print  |  Send  |  Refresh  |  Url
Type: Change Request Change Request
Priority: High High
Severity: Show Stopper Show Stopper
Status: Closed Closed
Resolution: Complete
Resources: Bob Denny
Reported By: Bob Denny
Component: Main Program
Fixed In Version: 6.0 Hot Fix 4
Versions Affected: 6.0 Hot Fix 3
Start Date: 11/23/2011
Percent Complete:
Created:  11/23/2011 8:40:37 AM
Revised:
 11/23/2011 10:24:09 AM
Closed:  11/23/2011 10:21:41 AM
Resolved:  11/23/2011 10:21:36 AM

The RCOS TCS (Azari) and the ASA Autoslew TCS throw errors when asked for the CanSetPierSide property. This is a required property per the ASCOM spec. However, it is unlikely that the RCOS controller will be fixed (obsolete). Since this was not a problem with ACP versions prior to HotFix 3, I'm going to make an exception to my rule and trap errors on those initial properties and default them instead of refusing to connect due to error.