Geminiclose
Gemini Password Reset

Please provide your username.

A password reset confirmation email will be sent to your email address.

Username
  • Projects

 
SCHEDULER-380 - Domes which rotate but have a manual shutter
Estimated: 0 Hours 30 Minutes   Logged: 0 Hours 35 Minutes   Excess Time: 0 Hours 5 Minutes
Print  |  Send  |  Refresh  |  Url
Type: Bug Bug
Priority: High High
Severity: Major Major
Status: Closed Closed
Resolution: Complete
Resources: Bob Denny
Reported By: Bob Denny
Component: Dispatch Scheduler Engine
Fixed In Version: 3.3
Versions Affected: 3.2
Start Date: 2/16/2010
Percent Complete:
Created:  2/16/2010 7:50:03 AM
Revised:
 2/16/2010 8:29:32 AM
Closed:  2/16/2010 8:29:32 AM
Resolved:  2/16/2010 8:29:21 AM

See this Comm Center thread. Need to check Dome.CanSetShutter in ACPSequencer.OpenDome() and CloseDome() and skip it if no shutter control.