Geminiclose
Gemini Password Reset

Please provide your username.

A password reset confirmation email will be sent to your email address.

Username
  • Projects

 
ACP-478 - Upside down Atik 16C on OAG - Reversed guide angle (patch made)
Estimated: 8 Hours 0 Minutes   Logged: 0 Hours 0 Minutes   Time Left: 8 Hours 0 Minutes
Print  |  Send  |  Refresh  |  Url
Type: Quirk Quirk
Priority: Medium Medium
Severity: Minor Minor
Status: Closed Closed
Resolution: Complete
Resources: Bob Denny
Reported By: Bob Denny
Component: AcquireSupport library
Fixed In Version: None
Versions Affected: 5.1 Hot Fix 11
Start Date: ?
Percent Complete:
Created:  11/4/2010 5:18:26 PM
Revised:
 2/5/2015 8:28:57 AM
Closed:  2/20/2013 11:24:20 AM
Resolved:  2/20/2013 11:24:19 AM

On Warren Keller's system, which has an Atik 16C guider on an off-axis pickoff, and which is mounted upside down with respect to the  main imager:
  1. Motion on the guide chip is N/S backward, failed to note E/W motion
  2. When calibrated in the East, it gets x = -3.7 y = 3.7 angle = -88. The guide angle should be around 180!
  3. In order to guide, additional logic had to be added to rotate the guide angle 180 if GemWest (looking west).
The logic for (3) is in AcquireSupport as of 6.0.1 but commented out. This needs to get looked at!